Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Sci (China) ; 123: 156-168, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36521981

RESUMO

Accurate and comprehensive knowledge of the atmospheric environment and its evolution within the coastal ocean boundary layer are necessary for understanding the sources, chemical mechanisms, and transport processes of air pollution in land, sea, and atmosphere. We present an overview of coastal ocean boundary layer detection technology and equipment in China and summarize the progress and main achievements in recent years. China has developed a series of coastal ocean boundary layer detection technologies, including Light Detection and Ranging (LIDAR), turbulent exchange analyzer, air-sea flux analyzer, stereoscopic remote sensing of air pollutants, and oceanic aerosol detection equipment to address the technical bottleneck caused by harsh environmental conditions in coastal ocean regions. Advances in these technologies and equipment have provided scientific assistance for addressing air pollution issues and understanding land-sea-atmosphere interactions over coastal ocean regions in China. In the future, routine atmospheric observations should cover the coastal ocean boundary layer of China.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Monitoramento Ambiental , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Oceanos e Mares , Tecnologia , China
2.
Opt Express ; 30(22): 40820-40841, 2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36299009

RESUMO

Determination of the correct water surface height (WSH) from green laser (532 nm) echoes alone in bathymetry LiDAR is challenging, as the green laser return near the water surface involves both specular reflection from the air-water interface and backscattered return from the water volume. In this paper, a low-complexity method based on linear approximation of the leading edge (LLE) is proposed. The results of this LLE method were compared with those of three common algorithms of peak detection, half peak power, and surface-volume-bottom implemented on airborne datasets with various surface roughness conditions. In addition, the method was evaluated in waters with a wide range of optical properties through a controllable tank experiment. The uncertainties in the WSHs of all algorithms were greater when the water volume backscattering dominated the surface return; they were sensitive to variations in the optical properties of water, and increased exponentially with decreasing LiDAR attenuation coefficient (KLiDAR). Comparatively, the LLE algorithm had the fastest computational speed and demonstrated the best performance in situations where specular reflection or volume backscatter return was dominant, with average and maximum errors of less than 0.06 and 0.13 m, respectively.

3.
Opt Express ; 30(8): 12848-12866, 2022 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-35472912

RESUMO

The forward volume scattering function (VSF) is an inherent optical property important in ocean lidar and underwater imaging and communication. The scattered power within 60° contains >90% of total scattered power, making it essential for determining the asymmetry parameter g. Thus, the new oblique-incidence-design Bettersize BT-3000 particle sizer was utilized to measure forward VSF (0.03°-60°) synchronously. A double-exponential model was then used to construct the full-angle-range VSF (0°-180°). The g value calculated therefrom had an uncertainty of <1%. Calibration was implemented using 11-µm beads alone, and the BT-3000's performance was validated.

4.
Sensors (Basel) ; 21(10)2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-34068048

RESUMO

We report the development of a laser gas analyzer that measures gas concentrations at a data rate of 100 Hz. This fast data rate helps eddy covariance calculations for gas fluxes in turbulent high wind speed environments. The laser gas analyzer is based on derivative laser absorption spectroscopy and set for measurements of water vapor (H2O, at wavelength ~1392 nm) and carbon dioxide (CO2, at ~2004 nm). This instrument, in combination with an ultrasonic anemometer, has been tested experimentally in both marine and terrestrial environments. First, we compared the accuracy of results between the laser gas analyzer and a high-quality commercial instrument with a max data rate of 20 Hz. We then analyzed and compared the correlation of H2O flux results at data rates of 100 Hz and 20 Hz in both high and low wind speeds to verify the contribution of high frequency components. The measurement results show that the contribution of 100 Hz data rate to flux calculations is about 11% compared to that measured with 20 Hz data rate, in an environment with wind speed of ~10 m/s. Therefore, it shows that the laser gas analyzer with high detection frequency is more suitable for measurements in high wind speed environments.

5.
Sci Rep ; 8(1): 2282, 2018 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-29396528

RESUMO

In estuarine and coastal ecosystems, the majority of previous studies have considered coupled nitrification-denitrification (CND) processes to be exclusively sediment based, with little focus on suspended particulate matter (SPM) in the water column. Here, we present evidence of CND processes in the water column of Hangzhou Bay, one of the largest macrotidal embayments in the world. Spearman's correlation analysis showed that SPM was negatively correlated with nitrate (rho = -0.372, P = 0.018) and marker genes for nitrification and denitrification in the water column were detected by quantitative PCR analysis. The results showed that amoA and nir gene abundances strongly correlated with SPM (all P < 0.01) and the ratio of amoA/nir strongly correlated with nitrate (rho = -0.454, P = 0.003). Furthermore, aggregates consisting of nitrifiers and denitrifiers on SPM were also detected by fluorescence in situ hybridization. Illumina MiSeq sequencing further showed that ammonia oxidizers mainly belonged to the genus Nitrosomonas, while the potential denitrifying genera Bradyrhizobium, Comamonas, Thauera, Stenotrophomonas, Acinetobacter, Anaeromyxobacter, Sulfurimonas, Paenibacillus and Sphingobacterium showed significant correlations with SPM (all P < 0.01). This study suggests that SPM may provide a niche for CND processes to occur, which has largely been missing from our understanding of nitrogen cycling in estuarine waters.


Assuntos
Desnitrificação , Nitrificação , Material Particulado/metabolismo , Microbiologia da Água , Bactérias/classificação , Bactérias/genética , Biota , China , Redes e Vias Metabólicas/genética , Nitratos/análise , Reação em Cadeia da Polimerase em Tempo Real , Água/química
6.
Opt Express ; 23(25): 32703-17, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26699060

RESUMO

Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

7.
Mar Pollut Bull ; 93(1-2): 163-71, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25697817

RESUMO

A field, light-weight laser fluorometer based on the method of laser induced fluorescence was developed for water quality monitoring. The basic instrument configuration uses a high pulse repetition frequency microchip laser, a confocal reflective fluorescent probe and a broadband hyperspectral micro spectrometer; it weights only about 1.7 kg. Simultaneous estimates of three important water quality parameters, namely, chlorophyll a (chl-a), colored dissolved organic matter (CDOM), and total suspended matter (TSM) measured by the laser fluorometer were observed to agree well with those measured by traditional methods (0.27-0.84 µg L(-3) chl-a, R(2)=0.88; 0.104-0.295 m(-)(1) CDOM absorption, R(2)=0.90; and 59.8-994.9 mg L(-)(3) TSM, R(2)=0.86) in Hangzhou Bay water. Subsequently, distribution and characteristics of CDOM and chl-a laser fluorescence in Hangzhou Bay were analyzed, which will enhance our understanding of biogeochemical processes in this complex estuarine system at high-resolution, high-frequency and long-term scale.


Assuntos
Monitoramento Ambiental/métodos , Poluentes da Água/análise , Baías/química , China , Clorofila/análise , Clorofila A , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/normas , Lasers , Luz , Qualidade da Água/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...